- Application of different Scheimpflug-based lens densitometry methods in phacodynamics predictionPublication . Faria-Correia, F; Lopes, BT; Ramos, IC; Monteiro, T; Franqueira, N; Ambrósio, RPURPOSE: To evaluate the correlations between preoperative Scheimpflug-based lens densitometry metrics and phacodynamics. METHODS: The Lens Opacities Classification System III (LOCS III) was used to grade nuclear opalescence (NO), along with different methods of lens densitometry evaluation (absolute scale from 0% to 100%): three-dimensional (3D), linear, and region of interest (ROI) modes. Cumulative dissipated energy (CDE) and total ultrasound (US) time were recorded and correlated with the different methods of cataract grading. Significant correlations were evaluated using Pearson or Spearman correlation coefficients according to data normality. RESULTS: A positive correlation was detected between the NO score and the average density and the maximum density derived from the 3D mode (r=0.624, P<0.001; r=0.619, P<0.001, respectively) and the ROI mode (r=0.600, P<0.001; r=0.642, P<0.001, respectively). Regarding the linear mode, only the average density parameter presented a significant relationship with the NO score (r=0.569, P<0.001). The 3D-derived average density and maximum density were positively correlated with CDE (rho =0.682, P<0.001; rho =0.683, P<0.001, respectively) and total US time (rho =0.631 and rho =0.668, respectively). There was a linear relationship between the average density and maximum density of the ROI mode and CDE (rho =0.686, P<0.001; rho =0.598, P<0.001, respectively) and total US time (rho =0.642 and rho =0.644, respectively). The average density was the only parameter derived from the linear mode that showed a significant correlation with CDE (rho =0.522, P<0.001) and total US time (rho =0.450, P<0.001). CONCLUSION: Specific Scheimpflug-derived densitometric parameters of the nucleus correlated with phacoemulsification parameters. The use of the appropriate densitometry approach can predict more efficiently the phacodynamics.
- Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens designPublication . Monteiro, T; Soares, AF; Leite, RD; Franqueira, N; Faria-Correia, F; Vaz, FPURPOSE: To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. METHODS: In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP®) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820®). RESULTS: YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 (p=0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm (p=0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm (p=0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups (p>0.05). CONCLUSION: YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant.
- Corneal biomechanics: Where are we?Publication . Luz, A; Faria-Correia, F; Salomão, MQ; Lopes, BT; Ambrósio, R
- Corneal Segment Rings Based on New Nomograms for Keratoconus: Surgical TechniquePublication . Sousa, K; Monteiro, T; Franqueira, N; Faria-Correia, F; Leite, R; Mendes, J; Vaz, F
- Effect of superior blepharoplasty on tear film: objective evaluation with the Keratograph 5M - a pilot studyPublication . Soares, AM; Faria-Correia, F; Franqueira, N; Ribeiro, SPURPOSE: To evaluate the effect of superior blepharoplasty on the tear film using the corneal topographer Keratograph 5M. METHODS: A prospective study was performed of 27 eyes of 14 patients with superior dermatochalasis who underwent superior blepharoplasty between May and June 2016. Conservative upper eyelid blepharoplasty was performed by an en bloc resection of anterior lamellar tissue that included skin, subcutaneous tissue, and the orbicularis oculi muscle. All the eyes were imaged using the noninvasive tear breakup time tools of the Keratograph 5M. The following parameters were recorded in each patient before and 6 weeks after surgery: first noninvasive Keratograph 5M tear breakup time (the time at which the first breakup of tears occurs) and average noninvasive Keratograph 5M tear breakup time (the average time of all breakup incidents). The exclusion criteria were ophthalmological pathology, previous eyelid surgery, use of eye drops, systemic pathology, and medication that interferes with lacrimal tears. RESULTS: The mean age of the patients was 65.1 years (range, 51-84); 86% were female. Student's t-test was used to compare the values of first and average noninvasive Keratograph 5M tear breakup times before and after surgery. The values for first noninvasive Keratograph 5M tear breakup time evaluated before and after surgery were not significantly different (9.04 and 8.71, respectively; p=0.926). The values for average noninvasive Keratograph 5M tear breakup time evaluated before and after surgery were also not significantly different (13.01 seconds and 13.14 seconds, respectively; p=0.835). CONCLUSIONS: The results of this pilot study suggest that upper blepharoplasty does not affect tear breakup time according to the objective evaluation of breakup time with the Keratograph 5M.
- Eficácia a los 12 meses en Lentes Intraoculares de Fijación en ÍrisPublication . Sousa, K; Monteiro, T; Ferreira, S; Franqueira, N; Leite, R; Faria-Correia, F; Mendes, J; Vaz, F
- Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataractPublication . Faria-Correia, F; Lopes, B; Monteiro, T; Franqueira, NC; Ambrósio, RPURPOSE: To test correlations between Scheimpflug optical densitometry and ocular higher-order aberrations (HOAs) in patients with mild nuclear cataract. SETTING: Cornea and Refractive Surgery Department, Hospital de Braga, Braga, Portugal. DESIGN: Retrospective single-center study. METHODS: In eyes with mild nuclear cataract, lens densitometry was evaluated by Scheimpflug imaging (Pentacam HR), which provided an objective quantification (mean density and maximum density) and grading (nuclear staging score) of the crystalline lens. A visual function analyzer that combines ray-tracing aberrometry and Placido disk-based topography (iTrace) was used to evaluate the total ocular and internal HOAs. RESULTS: The study comprised 40 eyes of 30 patients. The mean density of the lens nucleus was 8.99% ± 0.76% (SD) (range 7.5% to 10.8%), and the mean maximum density was 27.96% ± 6.97% (range 16.9% to 56.1%). Regarding the score of nuclear staging of the Scheimpflug device, 28 eyes had level 0 and 12 eyes had level 1. Significant positive correlations were found between the mean density and maximum density parameters and the internal HOAs (ρ = 0.661, P < .001 and ρ = 0.570, P < .001, respectively). CONCLUSIONS: There were significant correlations between the quantification parameters derived from Scheimpflug lens densitometry and ocular HOAs. The integration of these technologies can help in clinical decision making and in understanding the subjective symptoms of patients with mild nuclear cataracts. FINANCIAL DISCLOSURE: Dr. Ambrósio is a consultant to Oculus Optikgeräte GmbH, Alcon Surgical, Inc., and Carl Zeiss Meditec AG. None of the other authors has a financial or proprietary interest in any material or method mentioned.
- V4C ICL® Secondary To Ferrara® Ring Implantation in Keratoconus PatientsPublication . Sousa, K; Monteiro, T; Franqueira, N; Faria-Correia, F; Leite, R; Mendes, J; Vaz, F