Repository logo
 
Publication

Consensus Recommendations of the Multiple Sclerosis Study Group and Portuguese Neuroradiological Society for the Use of the Magnetic Resonance Imaging in Multiple Sclerosis in Clinical Practice: Part 1

dc.contributor.authorAbreu, P
dc.contributor.authorPedrosa, R
dc.contributor.authorSá, MJ
dc.contributor.authorCerqueira, J
dc.contributor.authorSousa, L
dc.contributor.authorDa Silva, AM
dc.contributor.authorPinheiro, J
dc.contributor.authorDe Sá, J
dc.contributor.authorBatista, S
dc.contributor.authorSimões, RM
dc.contributor.authorPereira, DJ
dc.contributor.authorVilela, P
dc.contributor.authorVale, J
dc.date.accessioned2018-07-06T10:53:36Z
dc.date.available2018-07-06T10:53:36Z
dc.date.issued2018-05-30
dc.description.abstractINTRODUCTION: Magnetic resonance imaging is established as a recognizable tool in the diagnosis and monitoring of multiple sclerosis patients. In the present, among multiple sclerosis centers, there are different magnetic resonance imaging sequences and protocols used to study multiple sclerosis that may hamper the optimal use of magnetic resonance imaging in multiple sclerosis. In this context, the Group of Studies of Multiple Sclerosis and the Portuguese Society of Neuroradiology, after a joint discussion, appointed a committee of experts to create recommendations adapted to the national reality on the use of magnetic resonance imaging in multiple sclerosis. The purpose of this document is to publish the first Portuguese consensus recommendations on the use of magnetic resonance imaging in multiple sclerosis in clinical practice. MATERIAL AND METHODS: The Group of Studies of Multiple Sclerosis and the Portuguese Society of Neuroradiology, after discussion of the topic in national meetings and after a working group meeting held in Figueira da Foz on May 2017, have appointed a committee of experts that have developed by consensus several standard protocols on the use of magnetic resonance imaging in the diagnosis and follow-up of multiple sclerosis. The document obtained was based on the best scientific evidence and expert opinion. Subsequently, the majority of Portuguese multiple sclerosis consultants and departments of neuroradiology scrutinized and reviewed the consensus paper; comments and suggestions were considered. Technical magnetic resonance imaging protocols regarding diagnostic, monitoring and the recommended information to be included in the magnetic resonance imaging report will be published in a separate paper. RESULTS: We provide some practical guidelines to promote standardized strategies to be applied in the clinical practice setting of Portuguese healthcare professionals regarding the use of magnetic resonance imaging in multiple sclerosis. CONCLUSION: We hope that these first Portuguese magnetic resonance imaging guidelines, based in the best available clinical evidence and practices, will serve to optimize multiple sclerosis management and improve multiple sclerosis patient care across Portugal.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationActa Med Port. 2018 May 30;31(5):281-289pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.23/1266
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.subjectDoenças Desmielinizantespt_PT
dc.subjectEsclerose Múltiplapt_PT
dc.subjectProtocolospt_PT
dc.subjectRessonância Magnéticapt_PT
dc.titleConsensus Recommendations of the Multiple Sclerosis Study Group and Portuguese Neuroradiological Society for the Use of the Magnetic Resonance Imaging in Multiple Sclerosis in Clinical Practice: Part 1pt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue5pt_PT
oaire.citation.startPage281-289pt_PT
oaire.citation.volume31pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AMP.pdf
Size:
326.8 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: