Repository logo
 
Publication

Application of different Scheimpflug-based lens densitometry methods in phacodynamics prediction

dc.contributor.authorFaria-Correia, F
dc.contributor.authorLopes, BT
dc.contributor.authorRamos, IC
dc.contributor.authorMonteiro, T
dc.contributor.authorFranqueira, N
dc.contributor.authorAmbrósio, R
dc.date.accessioned2016-05-04T14:00:34Z
dc.date.available2016-05-04T14:00:34Z
dc.date.issued2016
dc.description.abstractPURPOSE: To evaluate the correlations between preoperative Scheimpflug-based lens densitometry metrics and phacodynamics. METHODS: The Lens Opacities Classification System III (LOCS III) was used to grade nuclear opalescence (NO), along with different methods of lens densitometry evaluation (absolute scale from 0% to 100%): three-dimensional (3D), linear, and region of interest (ROI) modes. Cumulative dissipated energy (CDE) and total ultrasound (US) time were recorded and correlated with the different methods of cataract grading. Significant correlations were evaluated using Pearson or Spearman correlation coefficients according to data normality. RESULTS: A positive correlation was detected between the NO score and the average density and the maximum density derived from the 3D mode (r=0.624, P<0.001; r=0.619, P<0.001, respectively) and the ROI mode (r=0.600, P<0.001; r=0.642, P<0.001, respectively). Regarding the linear mode, only the average density parameter presented a significant relationship with the NO score (r=0.569, P<0.001). The 3D-derived average density and maximum density were positively correlated with CDE (rho =0.682, P<0.001; rho =0.683, P<0.001, respectively) and total US time (rho =0.631 and rho =0.668, respectively). There was a linear relationship between the average density and maximum density of the ROI mode and CDE (rho =0.686, P<0.001; rho =0.598, P<0.001, respectively) and total US time (rho =0.642 and rho =0.644, respectively). The average density was the only parameter derived from the linear mode that showed a significant correlation with CDE (rho =0.522, P<0.001) and total US time (rho =0.450, P<0.001). CONCLUSION: Specific Scheimpflug-derived densitometric parameters of the nucleus correlated with phacoemulsification parameters. The use of the appropriate densitometry approach can predict more efficiently the phacodynamics.pt_PT
dc.identifier.citationClin Ophthalmol. 2016 Apr 6;10:609-15.pt_PT
dc.identifier.doi10.2147/OPTH.S95993pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.23/1028
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.subjectCataratapt_PT
dc.subjectDensitometriapt_PT
dc.subjectTécnicas de Diagnóstico Oftalmológicopt_PT
dc.titleApplication of different Scheimpflug-based lens densitometry methods in phacodynamics predictionpt_PT
dc.typejournal article
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Clin Ophthalmol.pdf
Size:
1.78 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: